null

Sonifex RB-FS82DC Audio Failover Switcher

Sonifex

Write a Review
Price: $3,943.45
SKU:
SON-RB-FS82DC
Condition:
New
Availability:
Item not stocked locally. Can usally ship in from the UK within 2-3 weeks.
Shipping:
Calculated at Checkout
More Info:
8 Main I/O, 2 Standby I/O, DC PSU - 1U
Product Link:
https://www.sonifex.co.uk/redbox/rbfs82_ld.shtml
Manufacturers Part Number:
RB-FS82DC
Adding to cart… The item has been added

Product Overview

RB-FS82DC Audio Failover Switcher - (8 Main I/O, 2 Standby I/O, DC PSU - 1U)

The RB-FS82 8 + 2 audio failover switcher is an important tool in many critical areas in telecommunications and broadcast chains.

The device has 8 main + 2 standby, stereo analogue audio, AES/EBU digital audio and RS232 connections (both inputs and outputs) and can be configured via Ethernet for two main operational applications:

1. For switching of program sources to a standby destination in the event of a destination failure (‘Standbys to outputs’). Typically this would be audio encoders at a program distribution head end (for audio over IP, E1 or other bearer networks), with “N” x programs feeding “N” x encoders. If an encoder fails the audio destined for that encoder gets routed to a standby encoder so ensuring the continuity of audio to network transport.

2. Switching of program sources, including standby sources, to destinations in the event of source failure (‘Standbys to inputs’). Typically this would be audio decoders at a transmission site with “N” x programs and “N” x decoders feeding “N” x transmitters. If a decoder fails, the audio from a standby decoder, or other audio source such as an mp3 player, overrides the signal path to the transmitter so ensuring continuity on air.

The RB-FS82 supports any configuration of up to 8 main program signal paths (N = 8) and there are 2 standby program signal paths, in either mode of operation. Each program path simultaneously switches analogue L/R audio, AES/EBU digital audio and RS232 data. Each of these signals is wired on D-Type connectors on the rear panel.

All signal paths are passive and therefore completely transparent utilising relay based switching. This has the benefit of a “straight wire” topology during normal (alarm free) operation and also during any power outage to the device. An additional benefit of the passive signal path is AES/EBU bit transparency allowing throughput of AES/EBU AC3 Dolby E (TM) signals.

To ensure the passive nature of the device, switching is determined by alarm (General Purpose) inputs, with this alarm signalling in turn being normally provided by the encoder or decoders (or other devices) at site. Recognising the mission critical nature of the system, a high grade of relay is used in the RB-FS82.

The passive design ensures continuity of audio in the event of any power outage. However the RB-FS82 also includes dual redundant power supplies (85V-264V AC with a 12V 1A DC backup as standard). The RB-FS82-DC model accepts two DC power inputs (24 - 48V DC) via locking 2.5mm pin power connectors and both power supplies are monitored by the unit. This means that if either power supply fails, the other is ready to take over. In the extremely unlikely event that both fail, the unit’s passive signal path ensures a straight wire connection for all 8 program feeds (analogue, AES/EBU & RS232). This is essential for applications such as installation at transmitter sites, where a power failure to the unit will not prevent the audio input signal from being output to each of the supported 8 transmitters.

A row of LEDs on the front panel confirm the unit status, with each individual program path indicated as being in alarm with either Standby 1 or Standby 2 programs clearly confirmed as actively over-riding the failed signal. Alarm LEDs on the front panel are also indicated for power supply 1 failure and power supply 2 failure and these are mirrored by the device’s own General Purpose Outputs so facilitating easy interfacing of the device with the addition of a summary alarm status GPO.

By monitoring and acting on active low GPI Alarms for each signal path the unit can switch each main path between: Through, Standby 1, Standby 2 or Silence. The unit will always attempt to route a Standby path when a Main path alarm is detected and if both Standby paths are already in use, then one of the two remaining options (Through, Silence) will be used. The unit can be configured to either Automatically restore a Main ‘through’ path or wait for a Manual button press.

For more information on the Sonifex RB-FS82DC Audio Failover Switcher, click here!

Warranty Information

The Company agrees to repair or (at its discretion) replace Goods which are found to be defective (fair wear and tear excepted) and which are returned to the Company within the Warranty Term provided that each of the following are satisfied:
  1. (i) notification of any defect is given to the Company immediately upon its becoming apparent to the Purchaser;
  2. (ii) the Goods have only been operated under normal operating conditions and have only been subject to normal use (and in particular the Goods must have been correctly connected and must not have been subject to high voltage or to ionising radiation and must not have been used contrary to the Company's technical recommendations);
  3. (iii) the Goods are returned to the Company's premises at the Purchaser's expense;
  4. (iv) any Goods or parts of Goods replaced shall become the property of the Company;
  5. (v) no work whatsoever (other than normal and proper maintenance) has been carried out to the Goods or any part of the Goods without the Company's prior written consent;
  6. (vi) the defect has not arisen from a design made, furnished or specified by the Purchaser;
  7. (vii) the Goods have been assembled or incorporated into other goods only in accordance with any instructions issued by the Company;
  8. (viii) the defect has not arisen from a design modified by the Purchaser;
  9. (ix) the defect has not arisen from an item manufactured by a person other than the Company. In respect of any item manufactured by a person other than the Company, the Purchaser shall only be entitled to the benefit of any warranty or guarantee provided by such manufacturer to the Company.